Ultra-high-purity gases for the semiconductor industry.

The semiconductor industry tolerates neither interruptions nor impurities. Briskfil designs N5.0 and N6.0 nitrogen systems, Class 0 compressed air, and oxygen systems for wafer fabrication, packaging, and testing, with on-site generation, triple redundancy, and continuous monitoring. Where a single particle can destroy an entire batch, we specify the right purity level for each process.

250+

Installations delivered in Portugal and international markets

35anos

Applied engineering for industrial gases

Internationally recognised standards

Briskfil — Padrões reconhecidos internacionalmente

Compliance · Certifications

Recognised standards
internationally

  • SEMI F1 / F8 / F12

    Gas purity specifications for the semiconductor industry

  • ISO 14644-1

    Class 1 to Class 9 cleanrooms

  • ISO 8573.1:2010 Classe 0

    Oil-free compressed air

  • SEMI S2 / S8

    Environmental safety and ergonomics

  • Independent technical analyses

    Verifiable reports for audits

Each stage of chip manufacturing requires a different level of purity.

We work with wafer fabrication plants, foundries, outsourced semiconductor assembly and test (OSAT) facilities, and testing laboratories across all critical stages of the semiconductor manufacturing process. Each stage has different requirements for purity, dew point, particle levels, and flow rate, and we size the exact solution for each process chamber.

NXRD Glass Service Cards
Level 01Front-End

Chemical Deposition (CVD, ALD, Epitaxy)

Chemical deposition processes require N5.0 to N6.0 nitrogen as a purge and diluent gas, Class 0 compressed air for operating pneumatic valves, and inert atmospheres in reaction chambers. Any contamination from moisture or hydrocarbons can compromise the quality of the deposited film and wafer yield.

N₂ N6.0Class 0 AirPurgeInerting
Level 02Lithography

Lithography and ISO Class 1 Cleanrooms

EUV and DUV lithography require ISO Class 1 environments with ultra-filtered air and positive pressurisation maintained by oil-free compressed air with a dew point below −70°C. Nitrogen purges the optics and maintains an inert atmosphere in exposure chambers, protecting lenses worth hundreds of thousands of euros.

N₂ Ultra-PureClass 0 Compressed AirPressurisation
Level 03Etching and Cleaning

Etching, Wet Cleaning and CMP

Chemical etching and chemical mechanical polishing (CMP) processes use high-purity argon for sputtering, nitrogen for assisted drying, and compressed air to operate wafer-handling equipment. A dew point below −60°C is critical to prevent oxidation of newly etched surfaces.

Ar (Argon)N₂Dry AirPneumatics
Level 04Ion Implantation

Ion Implantation and Annealing

Ion implantation and rapid thermal annealing (RTA) processes require controlled atmospheres of ultra-high-purity nitrogen and argon to prevent metallic contamination. Load and unload systems (load locks) operate with continuous nitrogen purging between each wafer.

N₂ N5.5ArgonLoad Lock Purge
Level 05Packaging and OSAT

Packaging, Bonding and Testing (OSAT)

Back-end operations—including packaging, wire bonding, flip-chip assembly, and testing—use nitrogen to create inert atmospheres in curing ovens, Class 0 compressed air for pick-and-place and die-handling equipment, and vacuum for securing wafers and components. Consistency is just as critical as purity.

N₂Class 0 AirPick-and-placeCuring Oven
Level 06Testing and Burn-In

Testing, Burn-In and Characterisation

Testing laboratories and burn-in centres operate environmental chambers that combine nitrogen for moisture-free atmospheres, clean compressed air for probe card movement, and high-purity argon for electrical testing. Triple redundancy is essential to prevent multi-million losses.

N₂Class 0 AirArgonTriple Redundancy
Briskfil — Logo Reel

They trust us

Real installations. Visible engineering.

From engineering design to on-site delivery, we create installations built to last, monitored in real time and supported by certified technical teams.

Ready to optimise your installation?

Schedule a free audit of your compressed air or industrial gas systems. Receive a report with quantified potential savings — with no obligation.

Contact Us

Technology that protects yield in environments where a single particle can cost an entire batch.

In the semiconductor industry, a single particle larger than 0.1 micrometres can render an entire wafer—worth tens of thousands of euros—unusable. That is why the purity of the gases used is not simply an efficiency metric; it is a yield metric. Every tenth of a percentage point of yield lost in a fab can represent millions of euros in discarded product each year.


Engineering at the process level

Briskfil develops customised systems that combine on-site generation of ultra-high-purity nitrogen using PSA technology, ISO 8573-1:2010 Class 0 oil-free compressed air, and managed supply of specialty gases—including argon, helium, hydrogen, and dopant gases. Each solution is sized to match the actual requirements of each process chamber, with native integration into SCADA and MES systems.

Support from project to operation

Briskfil supports fabs and OSAT operations throughout every critical stage of the project. We begin with a comprehensive technical audit of existing facilities, size gas systems to the specific requirements of each process chamber, deliver the installation on a turnkey basis, and validate compliance with SEMI F1, F8, and F12 standards.

After commissioning, our team provides 24/7 preventive maintenance contracts with a guaranteed SLA response time of less than four hours. All technical documentation is prepared by our engineers to support successful customer audits, from major global brands to their respective supply chains.

On-site generation: the economic and strategic advantage.

For fabs with regular nitrogen consumption above 100 Nm³/h, transitioning to on-site generation combined with recovery systems typically delivers a payback period of between 18 and 36 months, with cumulative savings over more than a decade of operation. More importantly, it provides complete operational autonomy from disruptions in the global supply chain.

Explore our projects or request a free technical assessment for your facility.

Semiconductor Gases: Everything You Need to Know

From N6.0 purity to ISO Class 1 cleanrooms, everything behind a modern, efficient and productive fab.

It depends on the stage of the process. For back-end operations (packaging, testing, and pick-and-place), N5.0 nitrogen (99.999%) is generally sufficient. For front-end processes (lithography, CVD, ALD, and ion implantation), N5.5 (99.9995%) or N6.0 (99.9999%) nitrogen is typically required, with strict control of moisture (< 1 ppm), oxygen (< 1 ppm), and total hydrocarbons. EUV systems in advanced fabs may require N6.5 nitrogen with additional purification using catalytic getters.

The ISO 8573-1:2010 Class 0 standard defines compressed air with oil contamination controlled to levels specified by the equipment manufacturer and more stringent than Class 1 limits. In an ISO Class 1 cleanroom, where particle contamination is tightly controlled, any migration of oil from the compressed air system could irreversibly contaminate wafers and lithography optics. Briskfil uses certified oil-free compressors and multi-stage filtration systems with dew points down to −70°C.

Contamination is prevented through three layers: (1) generation and purification, using catalytic purifiers to remove O₂, H₂O and hydrocarbons; (2) distribution, through electropolished stainless-steel piping (Ra < 0.38 μm) with orbital welding and an inert atmosphere; and (3) continuous monitoring at every point of use using moisture, oxygen and particle analysers. Briskfil designs the entire chain—from the central supply system to the final point of use—with documented SEMI validation.

The semiconductor industry requires N+1 or N+2 redundancy across all critical systems. For nitrogen, this typically means two PSA generators operating in parallel, with a minimum autonomy of eight hours at maximum flow. For compressed air, a minimum of three compressors operating in parallel with automatic switchover is typically required. Systems must switch over without a pressure drop (< 50 ms) and generate alarms integrated into the factory’s MES.

"The questions we hear most often from those who operate, maintain and specify industrial systems."

Privacy Preference Center